Extra

Hikvision devices need to have their password entered from this tab.

Dahua devices need to have their username and password entered from this tab.


Used by JT Trace - if the JT Trace feature is enabled, this option will be selectable. It will allow the device to be used for Trace clockings.

Used by I/O Register - if selected then the transactions from the device will be included in calculating employee In/Out status.

Online and Offline SMS notification number - If enabled in System Configuration, cell numbers to notify of status can be entered.

The Change Room Device option will become available if selected in the System Configuration. When a device is marked as a Change Room Device and Change Room Devices are active on the day program, JT will ignore clockings from all Change Room Devices which occur before the first and after the last Non Change Room Devices. You can see more about this in the Day Program section.

Use Shift Control - option to include the device in Shift Control becomes available if the module is enabled, please see the Shift Control document for more information.

Use JT Live - If using Morpho hardware, this option can be activated to allow clockings to appear in Jarrison as soon as a reader is clocked on or to facilitate anti-passback or zoning (Access Pro module).

Deny Access on no response from JT Live - If the device is being used for Access Pro purposes, this setting instructs it to not allow access if the device loses communication with JT Live. (By default the device will allow anyone through if server communication is lost.)

Use Time Zone - Checking this option will allow use of a longitudinal time zone on the reader (not to be confused with Jarrison Time’s own time zone setting).

For IP devices the JT Engine PC is considered to be at 0 and time zone settings are relative to this (not UTC-based).

Webserver device time zone settings are based on GMT/UTC.

Use Daylight Saving - Selecting this option will activate Daylight Savings on the reader. Once selected, details of when savings should be applied must be configured appropriately.
    • Related Articles

    • 32.1 T & A Devices

      T & A Devices In some cases T&A Devices from external access control systems need to be defined within JT. This option is not available with all Import Locations (external access control databases). To setup the Time and Attendance terminals, click ...
    • 24.1 Devices/Details

      Devices Details Enabled - each device needs to be enabled to be included in the JT Engine’s list (viewable from the Device Action Monitor). Remote Clockings Import - if selected will disable all other parameters besides the device name and will ...
    • 18.1 Engine and Device Action Monitor

      Engine 1. The Engine is a service application which runs independently to Jarrison Time, and runs in the background on one designated computer. It is used to manage and monitor all communications to all of the devices linked to Jarrison Time and to ...
    • 24.3 Work Code

      Work Code Use device as a Job, with Work Code - If the Job Costing module is enabled, this option will allow the selected device to be used as a dedicated job reader i.e. transactions from this reader will always be for the same action on the same ...
    • 7.1 Setting up Additional Users on the Network

      Setting up Additional Users on the Network In order for multiple users to connect to the database via the network, the following changes need to be made to the server (PC) where the JT databases reside, to make communication possible. It is ...